Electrical installation into thermal insulation



KEZ

installation box into thermal insulation

Box serves to install instruments (plugs, switches) on the thermal-insulated facade of building. Its design eliminates creating of thermal-bridges.
Box enables to install the instruments with insulation wallthickness 50 - 200 mm.
Part of the package are dowels, twists for fixing the carrier to the wall, screws for mounting the box to the carrier and for instrument insulation.
There is necessary to install the instruments with IP corresponding with the environment.


dimension: 120 x 120 x 200 mm
material: halogen free, self-snuffing PP
temperature range: from -25 up to +60 °C

Package:



Instruction:



MDZ

mounting desk into thermal insulation

It serves for installation of devices (outside lights, movement sensors, plugs 400 V etc.) on thermal-insulated facade. Its design eliminates creating of thermal-bridges.
Mounting desk enables to install the instruments with insulation wall-thickness 50 - 200 mm.
Mounting area 120 x 120 mm.
Part of the package are dowels, twists for fixing the carrier to the wall, screws for mounting the desk to the carrier and for instrument insulation.


dimension: 120 x 120 x 200 mm
material: halogen free, self-snuffing PP
temperature range: from -25 up to +60 °C
load: max. 4 kg

Package:



Instruction:


1. There is necessary to cut the carrier including inserted insulation before installation depending on layer thickness insulation.


2. KEZ, KEZ-3 - installation box into thermal insulation
The carrier is fixed to the wall with twists and dowels depending on type of the wall surface.
Then you will put the cable through the carrier.
The box or desk can be fixed to the carrier with four screws (part of package).




KEZ 3

installation box into thermal insulation

enables the devices assembling into associated frames for thickness insulation from 100 to 250 mm
dimension: 120x120x250 mm

1. There is necessary to cut the carrier including inserted insulation before installation depending on layer thickness insulation.


2. MDZ - mounting desk into thermal insulation
The carrier is fixed to the wall with twists and dowels depending on type of the wall surface. For installation of 400 V plug we recommend to fasten the carrier with chemical anchors.
Then you will put the cable through the carrier.
The box or desk can be fixed to the carrier with four screws (part of package).